Surge Counter

Lightning counter is a means by which it is possible to keep electrical appliances safe from damage caused by lightning strikes to the device or building, thus obtaining the number of lightning strikes in the building. Due to the fact that the lightning strike next to this device prevents the entry of this high voltage into electrical appliances. The operation of the lightning counter is that there are two terminals connecting a high voltage terminal and the other to the earth, and when a powerful and fast voltage strikes the lightning counter, the device passes this voltage through its terminals to the ground. And so it protects electrical appliances.

What is Surge Counter?

A surge counter is a vital tool for protecting electrical equipment and buildings from lightning damage. This device allows the user to record the number of lightning strikes on a building and prevent high voltage from entering electrical equipment. This feature is especially important in areas with a high risk of storms and lightning, as the damage caused by this phenomenon can cause irreparable financial and human losses.

The way a surge counter works is that it has two terminals: one of them is connected to high voltage and the other to ground. When a strong and fast voltage enters the device, the counter transfers this voltage to ground and protects the electrical equipment. This process prevents excess energy from entering electrical systems and preventing them from being damaged. In this way, using a surge counter can help increase the useful life of electrical equipment.

A lightning arrester filters lightning to prevent damage to buildings and large factories.

Finally, the use of a lightning arrester counter not only improves the safety of electrical equipment, but also allows users to make better decisions in terms of protection and risk management by knowing the number of lightning strikes that have hit the building. This device is known as a safe investment in the safety of buildings and electrical equipment and demonstrates its effectiveness, especially in adverse and dangerous weather conditions.

Installing the lightning arrester counter

Installing the lightning arrester counter is very easy and only needs to be aligned with the conductor located below by tightening the 4 screws located in the retaining plate so that the lower conductor is located between both elements. Lightning is artificially produced in official and independent laboratories to properly test the lightning arrester counter. The lightning arrester counter has proven its efficiency and effective use through these tests, and it withstands lightning current (100 kV, 10/350 MHz) without damage or failure.

contact us on WhatsApp at 09890337892426.